Transceiver commands for Dell 10G switch 8132F (N4032F)

Switch ports are SFP+ and Transceiver modules are  SFP or SFP+ 

#show interfaces transceiver properties 

Yes: Dell Qualified        No: Not Qualified

N/A : Not Applicable

Port      Type    Media                 Serial Number         Dell Qualified

——— ——- ——————— ——————— ————–

Te1/0/1   SFP     1000BASE-LX           AL126817              Yes

Te1/0/2   SFP+    10GBASE-LR            AUN1MKR               Yes

 #show fiber-ports optical-transceiver

                                                       Output  Input
Port      Temp Voltage Current Power   Power   TX    LOS
                      [C]  [Volt]    [mA]  [dBm]   [dBm]   Fault

——— —- ——- ——- ——- ——- —– —

Te1/0/1    0.0 0.000       0.0  17.830  53.319       No    Yes
Te1/0/2   25.0 3.364      48.0  -1.401 -36.990    No    Yes

 Temp – Internally measured transceiver temperatures.

Voltage – Internally measured supply voltage.

Current – Measured TX bias current.

Output Power – Measured optical output power relative to 1mW.

Input Power – Measured optical power received relative to 1mW.

TX Fault – Transmitter fault.

LOS – Loss of signal.

 Large delay when running the above command when SFP is in port because it can’t get information

Bogus information for Te1/0/1 that is an SFP

 ————————————————————————————————————————–

 #show interfaces transceiver properties

 Yes: Dell Qualified        No: Not Qualified

N/A : Not Applicable

Port      Type    Media                 Serial Number         Dell Qualified
——— ——- ——————— ——————— ————–
Te1/0/1   SFP     1000BASE-LX           AL126820              Yes

 #show fiber-ports optical-transceiver

                                                      Output  Input
Port      Temp Voltage Current Power   Power   TX    LOS
                     [C]  [Volt]    [mA]  [dBm]   [dBm]    Fault

——— —- ——- ——- ——- ——- —– —

Te1/0/1    0.0 0.000       0.0  31.719  53.319       No    Yes

 

Temp – Internally measured transceiver temperatures.

Voltage – Internally measured supply voltage.

Current – Measured TX bias current.

Output Power – Measured optical output power relative to 1mW.

Input Power – Measured optical power received relative to 1mW.

TX Fault – Transmitter fault.

LOS – Loss of signal.

 —————————————————————————————————————-

 #show interfaces transceiver properties

 Yes: Dell Qualified        No: Not Qualified

N/A : Not Applicable

Port      Type    Media                 Serial Number         Dell Qualified
——— ——- ——————— ——————— ————–
Te1/0/1   SFP+    10GBASE-LR            AUE15UB               Yes
Te1/0/2   SFP+    10GBASE-LR            AUF18FZ               Yes

#show fiber-ports optical-transceiver

                                                              Output  Input
Port      Temp Voltage Current Power   Power   TX    LOS
                     [C]  [Volt]    [mA]  [dBm]   [dBm]   Fault
——— —- ——- ——- ——- ——- —– —

Te1/0/1   23.9 3.364      40.4  -1.393  -0.450    No    No
Te1/0/2   23.0 3.343      44.3  -1.442   0.090     No    No

 Temp – Internally measured transceiver temperatures.

Voltage – Internally measured supply voltage.

Current – Measured TX bias current.

Output Power – Measured optical output power relative to 1mW.

Input Power – Measured optical power received relative to 1mW.

TX Fault – Transmitter fault.

LOS – Loss of signal.

—————————————————————————————————————-

(config)#show line console ,  show line ssh, show ip ssh

exec-timeout 20

—————————————————————————————————————-

 #show interfaces transceiver properties

 Yes: Dell Qualified        No: Not Qualified

N/A : Not Applicable

Port      Type    Media                 Serial Number         Dell Qualified
——— ——- ——————— ——————— ————–

Te1/0/1   SFP     1000BASE-LX           AL126820              Yes
Te1/0/3   SFP+    10GBASE-LR            AUN12AU               Yes

 #show fiber-ports optical-transceiver

 

                                                            Output  Input

Port      Temp Voltage Current Power   Power   TX    LOS

                   [C]  [Volt]    [mA]  [dBm]   [dBm]   Fault
——— —- ——- ——- ——- ——- —– —

Te1/0/1    0.0 0.000       0.0  29.015  53.319      No    Yes
Te1/0/3   25.8 3.332      39.1  -1.433  -0.010     No    No

 Temp – Internally measured transceiver temperatures.

Voltage – Internally measured supply voltage.

Current – Measured TX bias current.

Output Power – Measured optical output power relative to 1mW.

Input Power – Measured optical power received relative to 1mW.

TX Fault – Transmitter fault.

LOS – Loss of signal.

 #show interfaces Tengigabitethernet 1/0/3 transceiver detail

 Type………………………… SFP+

Media……………………….. 10GBASE-LR

Serial Number………………… AUN12AU

Dell Qualified……………….. Yes

Data Rate……………………. multirate

Wavelength…………………… 1310

Receive Power………………… -0.002

#show interfaces Tengigabitethernet 1/0/1 transceiver detail

 Type………………………… SFP

Media……………………….. 1000BASE-LX

Serial Number………………… AL126817

Dell Qualified……………….. Yes

Data Rate……………………. UNKNOWN

Wavelength…………………… 1310

Receive Power………………… 53.319

 —————————————————————————————————————-

 #show fiber-ports optical-transceiver 

                               Output  Input
Port      Temp Voltage Current Power   Power   TX    LOS

          [C]  [Volt]    [mA]  [dBm]   [dBm]   Fault
——— —- ——- ——- ——- ——- —– —

Te1/0/1   25.3 3.336       7.8  -2.481  -1.245 No    No
Te1/0/2   29.2 3.332       7.6  -2.520  -1.273 No    No

 Temp – Internally measured transceiver temperatures.

Voltage – Internally measured supply voltage.

Current – Measured TX bias current.

Output Power – Measured optical output power relative to 1mW.

Input Power – Measured optical power received relative to 1mW.

TX Fault – Transmitter fault.

LOS – Loss of signal.

 #show interfaces transceiver properties

 Yes: Dell Qualified        No: Not Qualified

N/A : Not Applicable

Port      Type    Media                 Serial Number         Dell Qualified
——— ——- ——————— ——————— ————–

Te1/0/1   SFP+    10GBASE-SR            AM91JUS               Yes
Te1/0/2   SFP+    10GBASE-SR            AJB0FPG               Yes

 ———————————————————————————————–

 #show fiber-ports optical-transceiver

                                                     Output  Input
Port      Temp Voltage Current Power   Power   TX    LOS

                     [C]  [Volt]    [mA]  [dBm]   [dBm]   Fault
——— —- ——- ——- ——- ——- —– —

Te1/0/1   28.9 3.324       8.8  -2.463  -2.435 No    No
Te1/0/2   27.8 3.338       7.7  -2.239  -2.303 No    No

 Temp – Internally measured transceiver temperatures.

Voltage – Internally measured supply voltage.

Current – Measured TX bias current.

Output Power – Measured optical output power relative to 1mW.

Input Power – Measured optical power received relative to 1mW.

TX Fault – Transmitter fault.

LOS – Loss of signal.

 #show interfaces transceiver properties

 Yes: Dell Qualified        No: Not Qualified

N/A : Not Applicable

Port      Type    Media                 Serial Number         Dell Qualified
——— ——- ——————— ——————— ————–

Te1/0/1   SFP+    10GBASE-SR            AJB0GVX               Yes
Te1/0/2   SFP+    10GBASE-SR            AJB0G40               Yes

 —————————————————————————————–

PowerConnect 8132F – N4032F

 #show version

 Machine Description…………… Dell Networking Switch

System Model ID………………. N4032F

Machine Type…………………. Dell Networking N4032F

Serial Number………………… xxxxxxxxxxxxxxxxxxxxxxxxx

Manufacturer…………………. 0xbc00

Burned In MAC Address…………. F8B1.xxxxxxx

System Object ID……………… 1.3.6.1.4.1.674.10895.3044

CPU Version………………….. XLP308H-B1

SOC Version………………….. BCM56842_A1

HW Version…………………… 3

CPLD Version…………………. 17

 unit active      backup      current-active next-active

—- ———– ———– ————– ————–

1    6.3.0.18    6.2.6.6     6.3.0.18       6.3.0.18

(config)#ip default-gateway 199.x.x.x

Warning! Notice! The configured default gateway will not take effect until an interface belonging to the same subnet as the configured Gateway is created and activated.

 PowerConnect 8132F – N4032F

 #show version

 Machine Description…………… Dell Networking Switch

System Model ID………………. N4032F

Machine Type…………………. Dell Networking N4032F

Serial Number………………… xxxxxxxxxxxxxx

Manufacturer…………………. 0xbc00

Burned In MAC Address…………. D067.xxxxxxxxx

System Object ID……………… 1.3.6.1.4.1.674.10895.3044

CPU Version………………….. XLP308H-A1

SOC Version………………….. BCM56842_A1

HW Version…………………… 3

CPLD Version…………………. 17

 unit active      backup      current-active next-active

—- ———– ———– ————– ————–

1    6.3.0.18    6.2.7.6     6.3.0.18       6.3.0.18

 ————————————————————————————-

 #show ip vlan

 MAC Address used by Routing VLANs:   D067.E5AD.E4EF

            Logical

VLAN ID   Interface        IP Address       Subnet Mask
——-  ————–  —————  —————

1        Vl1             0.0.0.0          0.0.0.0

4xx      Vl4xx          199.x.x.x  255.255.255.252