Switch ports are SFP+ and Transceiver modules are SFP or SFP+
#show interfaces transceiver properties
Yes: Dell Qualified No: Not Qualified
N/A : Not Applicable
Port Type Media Serial Number Dell Qualified
——— ——- ——————— ——————— ————–
Te1/0/1 SFP 1000BASE-LX AL126817 Yes
Te1/0/2 SFP+ 10GBASE-LR AUN1MKR Yes
#show fiber-ports optical-transceiver
Output Input
Port Temp Voltage Current Power Power TX LOS
[C] [Volt] [mA] [dBm] [dBm] Fault
——— —- ——- ——- ——- ——- —– —
Te1/0/1 0.0 0.000 0.0 17.830 53.319 No Yes
Te1/0/2 25.0 3.364 48.0 -1.401 -36.990 No Yes
Temp – Internally measured transceiver temperatures.
Voltage – Internally measured supply voltage.
Current – Measured TX bias current.
Output Power – Measured optical output power relative to 1mW.
Input Power – Measured optical power received relative to 1mW.
TX Fault – Transmitter fault.
LOS – Loss of signal.
Large delay when running the above command when SFP is in port because it can’t get information
Bogus information for Te1/0/1 that is an SFP
————————————————————————————————————————–
#show interfaces transceiver properties
Yes: Dell Qualified No: Not Qualified
N/A : Not Applicable
Port Type Media Serial Number Dell Qualified
——— ——- ——————— ——————— ————–
Te1/0/1 SFP 1000BASE-LX AL126820 Yes
#show fiber-ports optical-transceiver
Output Input
Port Temp Voltage Current Power Power TX LOS
[C] [Volt] [mA] [dBm] [dBm] Fault
——— —- ——- ——- ——- ——- —– —
Te1/0/1 0.0 0.000 0.0 31.719 53.319 No Yes
Temp – Internally measured transceiver temperatures.
Voltage – Internally measured supply voltage.
Current – Measured TX bias current.
Output Power – Measured optical output power relative to 1mW.
Input Power – Measured optical power received relative to 1mW.
TX Fault – Transmitter fault.
LOS – Loss of signal.
—————————————————————————————————————-
#show interfaces transceiver properties
Yes: Dell Qualified No: Not Qualified
N/A : Not Applicable
Port Type Media Serial Number Dell Qualified
——— ——- ——————— ——————— ————–
Te1/0/1 SFP+ 10GBASE-LR AUE15UB Yes
Te1/0/2 SFP+ 10GBASE-LR AUF18FZ Yes
#show fiber-ports optical-transceiver
Output Input
Port Temp Voltage Current Power Power TX LOS
[C] [Volt] [mA] [dBm] [dBm] Fault
——— —- ——- ——- ——- ——- —– —
Te1/0/1 23.9 3.364 40.4 -1.393 -0.450 No No
Te1/0/2 23.0 3.343 44.3 -1.442 0.090 No No
Temp – Internally measured transceiver temperatures.
Voltage – Internally measured supply voltage.
Current – Measured TX bias current.
Output Power – Measured optical output power relative to 1mW.
Input Power – Measured optical power received relative to 1mW.
TX Fault – Transmitter fault.
LOS – Loss of signal.
—————————————————————————————————————-
(config)#show line console , show line ssh, show ip ssh
exec-timeout 20
—————————————————————————————————————-
#show interfaces transceiver properties
Yes: Dell Qualified No: Not Qualified
N/A : Not Applicable
Port Type Media Serial Number Dell Qualified
——— ——- ——————— ——————— ————–
Te1/0/1 SFP 1000BASE-LX AL126820 Yes
Te1/0/3 SFP+ 10GBASE-LR AUN12AU Yes
#show fiber-ports optical-transceiver
Output Input
Port Temp Voltage Current Power Power TX LOS
[C] [Volt] [mA] [dBm] [dBm] Fault
——— —- ——- ——- ——- ——- —– —
Te1/0/1 0.0 0.000 0.0 29.015 53.319 No Yes
Te1/0/3 25.8 3.332 39.1 -1.433 -0.010 No No
Temp – Internally measured transceiver temperatures.
Voltage – Internally measured supply voltage.
Current – Measured TX bias current.
Output Power – Measured optical output power relative to 1mW.
Input Power – Measured optical power received relative to 1mW.
TX Fault – Transmitter fault.
LOS – Loss of signal.
#show interfaces Tengigabitethernet 1/0/3 transceiver detail
Type………………………… SFP+
Media……………………….. 10GBASE-LR
Serial Number………………… AUN12AU
Dell Qualified……………….. Yes
Data Rate……………………. multirate
Wavelength…………………… 1310
Receive Power………………… -0.002
#show interfaces Tengigabitethernet 1/0/1 transceiver detail
Type………………………… SFP
Media……………………….. 1000BASE-LX
Serial Number………………… AL126817
Dell Qualified……………….. Yes
Data Rate……………………. UNKNOWN
Wavelength…………………… 1310
Receive Power………………… 53.319
—————————————————————————————————————-
#show fiber-ports optical-transceiver
Output Input
Port Temp Voltage Current Power Power TX LOS
[C] [Volt] [mA] [dBm] [dBm] Fault
——— —- ——- ——- ——- ——- —– —
Te1/0/1 25.3 3.336 7.8 -2.481 -1.245 No No
Te1/0/2 29.2 3.332 7.6 -2.520 -1.273 No No
Temp – Internally measured transceiver temperatures.
Voltage – Internally measured supply voltage.
Current – Measured TX bias current.
Output Power – Measured optical output power relative to 1mW.
Input Power – Measured optical power received relative to 1mW.
TX Fault – Transmitter fault.
LOS – Loss of signal.
#show interfaces transceiver properties
Yes: Dell Qualified No: Not Qualified
N/A : Not Applicable
Port Type Media Serial Number Dell Qualified
——— ——- ——————— ——————— ————–
Te1/0/1 SFP+ 10GBASE-SR AM91JUS Yes
Te1/0/2 SFP+ 10GBASE-SR AJB0FPG Yes
———————————————————————————————–
#show fiber-ports optical-transceiver
Output Input
Port Temp Voltage Current Power Power TX LOS
[C] [Volt] [mA] [dBm] [dBm] Fault
——— —- ——- ——- ——- ——- —– —
Te1/0/1 28.9 3.324 8.8 -2.463 -2.435 No No
Te1/0/2 27.8 3.338 7.7 -2.239 -2.303 No No
Temp – Internally measured transceiver temperatures.
Voltage – Internally measured supply voltage.
Current – Measured TX bias current.
Output Power – Measured optical output power relative to 1mW.
Input Power – Measured optical power received relative to 1mW.
TX Fault – Transmitter fault.
LOS – Loss of signal.
#show interfaces transceiver properties
Yes: Dell Qualified No: Not Qualified
N/A : Not Applicable
Port Type Media Serial Number Dell Qualified
——— ——- ——————— ——————— ————–
Te1/0/1 SFP+ 10GBASE-SR AJB0GVX Yes
Te1/0/2 SFP+ 10GBASE-SR AJB0G40 Yes
—————————————————————————————–
PowerConnect 8132F – N4032F
#show version
Machine Description…………… Dell Networking Switch
System Model ID………………. N4032F
Machine Type…………………. Dell Networking N4032F
Serial Number………………… xxxxxxxxxxxxxxxxxxxxxxxxx
Manufacturer…………………. 0xbc00
Burned In MAC Address…………. F8B1.xxxxxxx
System Object ID……………… 1.3.6.1.4.1.674.10895.3044
CPU Version………………….. XLP308H-B1
SOC Version………………….. BCM56842_A1
HW Version…………………… 3
CPLD Version…………………. 17
unit active backup current-active next-active
—- ———– ———– ————– ————–
1 6.3.0.18 6.2.6.6 6.3.0.18 6.3.0.18
(config)#ip default-gateway 199.x.x.x
Warning! Notice! The configured default gateway will not take effect until an interface belonging to the same subnet as the configured Gateway is created and activated.
PowerConnect 8132F – N4032F
#show version
Machine Description…………… Dell Networking Switch
System Model ID………………. N4032F
Machine Type…………………. Dell Networking N4032F
Serial Number………………… xxxxxxxxxxxxxx
Manufacturer…………………. 0xbc00
Burned In MAC Address…………. D067.xxxxxxxxx
System Object ID……………… 1.3.6.1.4.1.674.10895.3044
CPU Version………………….. XLP308H-A1
SOC Version………………….. BCM56842_A1
HW Version…………………… 3
CPLD Version…………………. 17
unit active backup current-active next-active
—- ———– ———– ————– ————–
1 6.3.0.18 6.2.7.6 6.3.0.18 6.3.0.18
————————————————————————————-
#show ip vlan
MAC Address used by Routing VLANs: D067.E5AD.E4EF
Logical
VLAN ID Interface IP Address Subnet Mask
——- ————– ————— —————
1 Vl1 0.0.0.0 0.0.0.0
4xx Vl4xx 199.x.x.x 255.255.255.252